1
I ordered the generator head inspected and it is every thing he says and more! Very pleased with the seller! Rich worked with me on the shipping and dealing with the details of shipping 400LBS. 2900 miles or so, IE Mass. to WA. state I bought it to put in a MEP-3A gen set.
John sends IE Tiger

3
Listeroid Engines / Re: From a 12/1 to a 16/1 to a 30/2...and a question
« on: September 08, 2021, 03:21:32 AM »
I think this post is spot on, I'm fighting a lister Petter now and can't wait to do this My IR meter is all over the map.

4
Petteroids / Re: Petter Mclaren B2 Valves
« on: July 11, 2021, 03:32:14 AM »
contact dieselman in Kanas email gary@dieselgen.com

5
Generators / Re: shot slip rings
« on: July 28, 2020, 02:42:25 AM »
new slip ring assy's on amazon measure shaft diameter carefully. mine came from GA USA I think

6
Changfa Engines / Re: Need help with Jiang Dong 1115
« on: September 21, 2019, 03:52:03 AM »
I'm prone to the injector dribble theory.

7
General Discussion / Re: Welding on clean DC
« on: May 28, 2019, 02:37:25 AM »
Any one try one of these?
WWW.multiplaz.com

8
Listeroid Engines / Re: Video of current setup
« on: December 31, 2018, 04:01:39 AM »
Was'nt there discussion about the air flow thru the gen head for cooling?

9
General Discussion / Re: Metal working files
« on: December 29, 2018, 03:20:09 AM »
A carding brush and muriatic acid helps a lot on old files.

10
Everything else / Re: DIY Low EMF 5 step Sine Inverter
« on: August 24, 2018, 04:43:47 AM »
52 years ago tomorrow I was on my honey moon near Shaver lake California at her cousins cabin. under the eves were 1 pint mason canning jars upside down glued to the underside of the roof. The bottom metal screw on cap had a shot gun shell punched through it, the shot removed. I asked later what? they were filled with Borate and or baking soda. The 99 year lease from the forest service was expiring and they told the owners no renewal and no fire support any more. later a land trade was made and a volenteer fire Dept formed. they would not cover homes with the bombs installed. with the plastic bottles available now they could work even better with reduced risk to fire fighters. I was told a house fire starts under the Eves in a clockwise swirl, the bombs go off and the structure has another chance all be it slim. Maybe south of the equator the swirl goes counter clockwise? We have smoke from Canada BC and Olympics and Cascades, but nothing close. Wishing you all the best

11
Original Lister Cs Engines / Re: New member
« on: August 04, 2018, 03:27:39 AM »
you do not need a manual. Go to the WOK pages drill to 38AC and you will have far better info than the original manual.
2 start your own thread.
have fun and good luck.

12
Lister Based Generators / Re: 6Kw Markon
« on: June 15, 2018, 03:26:32 AM »
I would say not, with only 4 wires.

13
Lister Based Generators / Re: 6Kw Markon
« on: June 15, 2018, 03:12:20 AM »
To me it looks like a 2 pole alternator 4 wire can be wired in series or parallel to achieve 240 volt or  and 120 volt and 120 volt only with lots of amps. the cap could mean brushless, look for diodes mounted on rotor. with only four leads no way a starter generator.

14
General Discussion / Re: The future of electric Vehicles.
« on: May 19, 2018, 03:40:10 AM »
Some thing else to consider is the Vanadium flow batteries coming on line. Invented or made somewhat practical in OZ by a college student She developed a battery that stores the energy in the electrolyte and its capacity is determined by the amount of electrolyte one can store. They are practical so far only for stationary applications as large amounts of electrolyte are required. Several versions of electrolyte work including common sulfuric acid types. Many company's working on it, 1 in my neck of the woods, UNI Energy Technologys of Mulkilteo WA. USA.
There are several prototypes over 1 megawatts in operation.

15
Listeroid Engines / Re: The twin build
« on: December 30, 2017, 02:34:56 AM »
As before I saved some bandwidth by not documentin the tear down. We are now at the point of beginning. Beside the normal cleaning we have some modifications to preform. As shipped there is no way to check the oil level or add oil except by removing  the crankcase cover. We will be addressing that during  block prep.

looking at the block pic my metro 12/2 center crank bearing supported by bolts from the top, yours from the block casting from the base? any comments?