Things I want to Buy / Re: Looking to buy CS 5-1 or 6-1
« on: January 17, 2017, 07:51:54 PM »
Cheers for that I will keep an eye out
Regards Ron.

2
Things I want to Buy / Looking to buy CS 5-1 or 6-1
« on: January 16, 2017, 06:18:02 PM »
Hi folks, I'm looking to buy a CS engine complete if possible or one that doesn't need a complete refurb. I'm located in Warwickshire UK and I don't mind travelling to get one. There doesn't seem to be many on flea bay at the moment. Any advice gratefully accepted.
Regards Ron.

3
Lister Based Generators / Re: Help needed ST3 SOM Brush 10.5 kva
« on: February 25, 2016, 05:55:05 PM »
Thanks you guys I'm on my way to sorting it.

4
Lister Based Generators / Re: Help needed ST3 SOM Brush 10.5 kva
« on: January 20, 2016, 01:48:39 PM »
Hi mr X any info would be greatly appreciated I would imagine they used similar components in all the Brush generator heads this forum is amazing with all the knowledge on here. Could you email it to haleron@hotmail.com please.
Thanks
Ron.

5
Lister Based Generators / Re: Help needed ST3 SOM Brush 10.5 kva
« on: January 19, 2016, 08:20:04 PM »
After a little more delving it would appear the big resistor has been removed along with the switch would anyone know the correct size of resistor that I need to find please?
Regards Ron.

6
Lister Based Generators / Help needed ST3 SOM Brush 10.5 kva
« on: January 19, 2016, 12:15:39 PM »
Hi everyone what a super forum for information. I have been trawling through some of the posts on here. And its a wealth of knowledge. I think I've got the bug.
I have just bought a ST3 SOM with a 10.5 kva head made by Brush. There are a couple of bits missing which I have ordered from the internet, however the high/low battery switch has been removed and the wires cut in the box on top of the generator. there are 3 wires one thick wire labelled (5) and two black wires one coming from the fuse and one coming out of the genny with the thick wire. I don't know what type of switch was originally fitted i.e. rotary or a toggle and I don't have a connection diagram. Can you guys help me out.
Also would I be correct in thinking that this set requires 24 volts to start as someone told me they can be 12v or 24v.
As I'm a newbie I am struggling to add some pictures but the plant nos. are engine 130ST326 and the generator is 130 STI 26 V S0  its single phase 240v.